M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.17 Device Menus
6.17.3.8 Starting and Stopping the Monitor for the Selected Device
(1) Refer to "Entering Devices for Monitoring" and enter the device you want to monitor into the list.
(2) Press the [CHANGE DISPLAY FORMAT] menu and select whether the current value is displayed in a 16-bit display, a
32-bit display, a single precision display, a double precision display, and a string display
(3) Press the [DEC/HEX] menu and select whether the current value is displayed in decimal or hexadecimal numbers.
(4) Press the [START/STOP MONITOR] menu to start the monitor. Starting the monitor moves the focus to the list. [MONI-
TOR] is also displayed in the top-right of the screen.
(5) Use the up/down arrow keys, Page Up key, and Page Down key to move within the list and check the monitoring status of
other specified devices.
Stopping the monitor
(1) Pressing the [START/STOP MONITOR] menu key while monitoring devices stops the monitor. The [MONITOR] display in
the top-right of the screen is also canceled.
6.17.3.9 Closing the Entry Device Monitor Screen
Use any of the following methods to close the entry device monitor popup screen.
Methods to close the screen
Press the [CLOSE] menu key.
Press the left arrow key.
Press the [ESC] key on the software keyboard.