M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.5 Common Items

5.5.5.2 Operating Procedures

Start the operation screen by the following operation on GX Works2.
[Project] -> [New]
Set the PLC series, PLC type, and project name, which are required to create a new project, in the following window.
(1)
(2)
(3)
(4)
(5)
Set the following items, and press [OK] in the "New Project" window.
(1) Series
Set the series name of the PLC (Programmable controller). Select "QCPU (Q mode)" here.
(2) Type
Set the type of the PLC. Set "Q26UDH" here.
(3) Project type
Set the project type. To create a sequence program (without labels), select "Simple Project".
To create a sequence program (with labels), select "Simple Project" or "Structured Project".
To create a sequence program in ST language, select "Simple Project" or "Structured Project".
(4) Use Label
To create a sequence program (with labels), check the "Use Label" checkbox.
To use function blocks and labels, check the "Use Label" checkbox.
To use ST language in a simple project, check the "Use Label" checkbox.
Note
 Even when labels are used, the built-in PLC (built-in edit function) displays an actual unlabeled ladder (ladder with
labels and functional blocks compiled).
 When "Structured Project" is selected, this setting becomes non-selectable. (Labels are used by default.)
(5) Language
Set the programming language. To create a sequence program (without labels, with labels), select "Ladder".
To create a sequence program in ST language, select "ST".