Mitsubishi Electric M800VW Series Manual page 354

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.11 Basic Operation
To use multiple projects
Procedure
Start
Main
Select the current project.
Main
Transition to the ladder
screen.
Main/ladder
Stop the PLC.
PLC RUN/STOP
Main/ladder
Edit the ladder.
Main/ladder
Monitor the ladder.
Main/ladder
Main/ladder
Run the PLC.
PLC RUN/STOP
Main/ladder
Test the device.
Switch programs.
Main/ladder
Return to the main screen.
Main/ladder
Complete
Operation
Screen position
SELECT PROJECT
LADDER
PLC RUN/STOP
STOP EXECUTE
EDIT
Edit the ladder.
CONVERT LADDER
MONITOR
PLC RUN/STOP
RUN EXECUTE
DEVICE TEST
Test the device.
PROGRAM CHANGE
Switch to a program that has
not yet been edited.
Menu button
Select the current operation project.
PLC data is automatically read and the
system transitions to the ladder screen.
The monitor also automatically starts.
Display the PLC RUN/STOP popup
screen.
Stop the PLC.
Switch to the edit mode.
Edited ladder data is confirmed by
conversion operation.
Switch to the monitor mode.
Display the PLC RUN/STOP popup
screen.
Run the PLC.
Display the device test popup screen.
Repeat the edit and debug procedure
until the debug results are correct.
Display the switch program screen.
Continue switching programs until all
sequence programs have been edited
and debugged.
Return to the main screen.
Select the project at the main screen
to select a different project storing the
sequence program to be edited.
329
IB-1501614-B

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800vs seriesM80vw seriesM80v seriesM850vwM830vwM850vs ... Show all

Table of Contents