M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.5 Common Items
(3) The following screen is displayed.
The free capacity displayed on this screen is equivalent to the actual capacity of the CNC controller.
When there is not enough free capacity, secure the required capacity before writing data.

5.5.12.2 Precautions

(1) When the source information is selected, the program is also selected automatically. Actual free capacity is the sum of
displayed free capacity selected in the [Online] tab and the file size of the program.
(2) When an item such as comment files and source information of the user safety sequence is selected, the file size on GX
Works2 and that on CNC is calculated in double. Therefore, free capacity displayed in the [Online] tab is smaller than the
actual size.
To confirm whether the CNC has enough free capacity to write the comment file and source information of the user safety
sequence, compare the total file size displayed in the [Offline] tab and the storable data size of the comment for the user
safety sequence.
For the user safety sequence, refer to "M800/M80 Series Smart safety observation Specification manual".