Backup Data Restoration; Precautions - Mitsubishi Electric M800VW Series Manual

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.14 Backing Up Sequence Programs and Other Data

5.14.1.3 Backup Data Restoration

To restore backup data, perform the reversed backup operation (Enter the setting for the personal computer in [A:Dev], and
the setting for CNC controller in [B:Dev]).
The PLC must be STOP before restoration is started.

5.14.1.4 Precautions

Precautions for input/output between different NC models or between systems with different additional
specification status
If the large capacity PLC (256 kilo steps)/large capacity PLC (512 kilo steps) additional specification is enabled, the size of
sequence programs that can be stored in CNC is increased.
USERPLC.LAD output while Large PLC capacity (256 kilo steps)/Large PLC capacity (512 kilo steps) additional specification
is enabled may not be input to the system in which the enabling/disabling of Large PLC capacity option is switched,
depending on the size of the sequence programs stored when output.
[Large capacity PLC additional specification, type of input USERPLC.LAD, and operation]
Large capacity PLC additional specification is
disabled in M800V series
Large capacity PLC (256 kilo steps) additional
specification is enabled in M800V series
Large capacity PLC (512 kilo steps) additional
specification is enabled in M800V series
When the PLC project extension (3 projects)/PLC project extension (6 projects) (additional specification) is enabled, the
number of projects and device points that can be used increases when the multi-project function is active.
The USERPLC.LAD output while the PLC project extension (3 projects)/PLC project extension (6 projects) (additional
specification) is enabled may not be input to the system whose PLC project extension option is switched between enabling/
disabling, depending on the number of projects and device points set at the time of the output of USERPLC.LAD file.
[PLC project extension additional specification, type of input "USERPLC.LAD", and operation 1]
PLC project extension additional speci-
fication is disabled in M800V series
PLC project extension (3 projects) addi-
tional specification is disabled in M800V
series
PLC project extension (6 projects) addi-
tional specification is disabled in M800V
series
[PLC project extension additional specification, type of input "USERPLC.LAD", and operation 2]
PLC project extension additional speci-
fication is disabled in M800V series
PLC project extension (3 projects) addi-
tional specification is disabled in M800V
series
PLC project extension (6 projects) addi-
tional specification is disabled in M800V
series
Inputting USERPLC.LAD that was output
when it contained more than 256 kilo
steps sequence programs.
The error "Can't write file for dev B" is gen-
erated.
The error "Can't write file for dev B" is gen-
erated.
Writing and PLC execution is possible.
Inputting "USERPLC.LAD" that was output
when the maximum project No. was set to 4
or larger
The error "Can't write file for dev B" is generat-
ed.
The error "Can't write file for dev B" is generat-
ed.
Writing and PLC execution is possible.
Inputting "USERPLC.LAD" that was output when a number which was larger than the
standard (*1) was set as the number of device points.
The error "Can't write file for dev B" is generated.
The error "Can't write file for dev B" is generated.
Writing and PLC execution is possible.
237
Inputting "USERPLC.LAD" that was out-
put when the following was true:
128 kilo steps < Number of contained se-
quence program steps ≤ 256 kilo steps
The error "Can't write file for dev B" is gener-
ated.
Writing and PLC execution is possible.
Writing and PLC execution is possible.
Inputting "USERPLC.LAD" that was output
when the maximum project No. was set to 2
or 3
The error "Can't write file for dev B" is generat-
ed.
Writing and PLC execution is possible.
Writing and PLC execution is possible.
IB-1501614-B

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800vs seriesM80vw seriesM80v seriesM850vwM830vwM850vs ... Show all