6 Explanation of Built-in Editing Function (PLC On-board)
6.11 Basic Operation
Backing up the sequence programs
An external device such as an SD card or USB memory is required to backup sequence programs. Perform these operations
after mounting an external device.
To use only one project
Procedure
After the PLC on-board starts, the system automatically reads
PLC data and transitions to the ladder screen. The monitor
Start
also starts.
Ladder
Return to the main screen.
Main
PLC data stored in the NC
is stored in external
devices.
Main/External file operation
Main/External file
operation/NC -> External
Save external project
Main/External file operation
Return to the main screen.
Complete
Operation
Screen position
Menu button
EXT. FILE OPERATION
NC -> EXT.
SELECT/CANCEL
WRITE
PATH
PROJECT NAME
TITLE
SELECT
313
Select the data to back up.
The save external project screen
displays.
Enter the [Project Name], [Title], and
[Path] used to store the backup PLC
data.
Run the [Select] operation after
entering the path.
Return to the main screen.