Plc Data; Plc Data Used By The Plc On-Board - Mitsubishi Electric M800VW Series Manual

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)

6.6 PLC Data

6.6 PLC Data

6.6.1 PLC Data Used by the PLC On-board

The PLC On-board uses the same data as GX Developer/GX Works2 as illustrated in the following table.
Data type
Sequence programs
PLC messages
Symbolic information
Device comments
Parameters
Trace files
CSV files
(*1) Characters that cannot be used in data names
 Reserved characters (AUX, CON, PRN, NUL, COM1 to COM9, LPT1 to LPT9, and CLOCK$)
 Data names that include these characters result in error: ", =, |, :, ;, ,, \, [, ], +, *, ?, <, >, . and /
The following characters also cannot be used.
 Special NEC selected IBM extended characters (character codes: 0xED40 to 0xEEEC)
 IBM extended characters (character codes: 0xFA40 to 0xFC4B)
 Characters of character codes that have the same appearance as NEC selected IBM extended characters and IBM
extended characters within the range of character codes 0x849F to 0x879C
Example: Roman numerals (I to X), ≒ , ≡ , ∫ , ∮ , Σ, √ , ⊥ , ∠ , ⊿ , ∵ , ∩ , ∪ , № , ℡ , and ㈱ .
If any of these characters are used, processing that uses PLC data (opens, saves, etc.) will not execute correctly.
(*2) Characters that can be used to set data names
Alphanumeric characters, Kana (Japanese syllabaries), Chinese characters, and these characters: _, ^, $,  ̄, ~ (tilde), !,
#, %, &, (, ), -, {, }, @ and '
(*3) Use the following method to change names of PLC message data.
 Specify bits 0-2 (3 bits) of bit selection parameter #6453 (Language selection method using only the PLC).
Data type
Program
 Specify with the display language selection parameter (Base specification parameter #1043 (Method linked with lan-
guage selection on the setting and display screens)).
Data type
Program
IB-1501614-B
Data name
Data names are configured by up to eight one-
byte uppercase alphanumeric characters.(*1)
Data names are configured by up to eight one-
byte uppercase alphanumeric characters (*1)
and in accordance with PLC message naming
conventions (*3).
Parameter names are fixed and cannot be
changed.
Data names are configured by up to eight one-
byte uppercase alphanumeric characters.(*1)
Parameter names are fixed and cannot be
changed.
Data names are configured by up to eight one-
byte uppercase alphanumeric characters.(*1)
Data names are configured by up to eight one-
byte uppercase alphanumeric characters.(*1)
Data name
M1xxxxxx
PLC message in the 1st language
:
M7xxxxxx
PLC message in the 7th language
M8xxxxxx
PLC message in the 8th language
Data name
M00xxxxxx
PLC messages for language parameter 0 (English)
M01xxxxx
PLC messages for language parameter 1 (Japanese)
:
M25xxxxx
PLC messages for language parameter 25 (Czech)
294
Application
The user PLC, statements, and notes are
stored.
PLC messages (alarms, operators, PLC switch-
es, and comments) are stored.
Store sequence programs and PLC messages
of the project with labels or structured project.
Comments and device names are stored.
Program execution sequences and such are
stored.
The trace conditions and results are stored.
The trace results are stored in CSV file format.
Details of data
Details of data

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800vs seriesM80vw seriesM80v seriesM850vwM830vwM850vs ... Show all

Table of Contents