Outline
After the trace execution, the collected trace results can be displayed in chronological order. Also the output results can be
written to the external devices in CSV file format.
Bit device
Word device
Common
IB-1501614-B
Displayed device field This displays the trace result of bit device (connect/coil) on the up-
per side of screen.
The changes of the devices are displayed in chronological order
based on the trigger point as a base point "0".
Count
This displays the number of traces at the cursor position in the bit
device display field.
Time
This displays the trace time (h:m:s) at the cursor position in the bit
device display field.
Disp. units
The displayed scale (number of traces to be displayed) can be
changed with the following range.
10 (Default), 20, 50 and 100
Displayed device field This displays the word devices (Current values) on the lower
screen.
The value change is displayed in chronological order based on the
trigger point as a base point "0".
Count
This displays the number of traces at the cursor position in the
word device display field.
Time
This displays the trace time (h:m:s) at the cursor position in the
word device display field.
Disp. units
16BIT DEC (Default)
16BIT HEX
32BIT DEC
32BIT HEX
FLOAT (Single Precision)
FLOAT (Double Precision)
String
To display the "32BIT" or "FLOAT (Single Precision)", upper or
lower device is required to configure in the trace data setup.
To display the "FLOAT (Double Precision)", set the specified de-
vice and three sequence devices.
Device change
This moves the cursor between bit device display field and word
device display field. The screen with the cursor can be scrolled to
display the result details.
Disp. units
This changes the unit to be displayed in the bit device display field
or word device display field where the cursor is on.
Adjust position
This changes the display position of other screen (e.g. word device
display field) based on the cursor position of the screen with the
cursor . (e.g. bit device display field).
Line change (up)
This moves up the device with the cursor in the bit device display
field or word device display field.
Line change (down)
This moves down the device with the cursor in the bit device dis-
play field or word device display field.
Page left feed
This moves the display position to the left for 1 page on the cursor
located screen in the bit device display field or word device display
field.
Page right feed
This moves the display position to the right for 1 page on the cursor
located screen in the bit device display field or word device display
field.
Left scroll
This moves the trace result to the left for 1 trace on the cursor po-
sitioned screen in the bit device display field or word device display
field.
Right scroll
This moves the trace result to the right for 1 trace on the cursor po-
sitioned screen in the bit device display field or word device display
field.
Create CSV file
This enables the trace results to output (write) to the external file
in CSV file format.