Verifying Plc Data; Closing The Verify External File Screen - Mitsubishi Electric M800VW Series Manual

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.14 External File Operation Menus

6.14.7.6 Verifying PLC Data

Normal operation
(1) Press the [VERIFY SOURCE] menu key to move the focus to the verify source (NC) data. Use the up and down arrow
keys to select PLC data to verify. Use the [SELECT/DELETE DATA] menu key or the SP key to select the check boxes
for the desired PLC data.
(2) Press the [SELECT EXTERNAL PROJECT] menu key to display the select external project popup screen. Select the
project data to verify in the select external project popup screen.
(*) Refer to "6.14.3 Select External Project Popup Screen" for more information on operations within the select external
project popup screen.
(3) Press the [VERIFY SOURCE] menu key to move the focus to the verify destination (external) data. Use the up and down
arrow keys to select the category of PLC data as selected for the verify source data. Use the [SELECT/DELETE DATA]
menu key or the SP key to select the check boxes for the desired PLC data.
(4) After selecting data, press the [EXECUTE] menu key. Pressing this menu key compares the verify source PLC data with
the verify destination PLC data and then displays the verify results popup screen.
(*) Refer to "6.14.8 Verify Results Popup Screen" for more information on the operations within the verify results popup
screen.
If a password to protect reads/writes has been registered to the selected files, the cancel password screen is displayed.
Enter the password to cancel the password.
If the password is canceled, processing will continue.
Refer to "6.21 Canceling File Passwords" for information on clearing passwords.
Abnormal operation
This information describes the details of error messages displayed on the verify external file screen and the corrective action
thereof.
Error message
Verify source PLC data is not selected.
Select verify source PLC data and exe-
cute again.
Verify destination PLC data is not se-
lected. Select verify source PLC data
and execute again.
Different types of data are selected.
Check the files and execute again.

6.14.7.7 Closing the Verify External File Screen

 Use any of the following methods to close the verify external file screen.
Methods to close the screen
Press the [CLOSE] menu key.
Press the left arrow key.
Press the [ESC] key on the software keyboard.
IB-1501614-B
Error details
This is displayed when the [EXECUTE]
menu key is pressed before any PLC
data has been selected from the dis-
played verify source data list.
This is displayed when the [EXECUTE]
menu key is pressed before any PLC
data has been selected from the dis-
played verify destination data list.
This is displayed when the [EXECUTE]
menu key is pressed when the types of
PLC data selected for the verify source
data list and the verify destination data
list are different.
428
Remedy
Select PLC data from the displayed ver-
ify source data list before pressing the
[EXECUTE] menu key.
Select PLC data from the displayed ver-
ify destination data list before pressing
the [EXECUTE] menu key.
Select the same types of data from the
verify source data list and the verify
destination data list and then press the
[EXECUTE] menu key again.