Setting Execution Projects - Mitsubishi Electric M800VW Series Manual

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.18 Parameter Menus

6.18.5.7 Setting Execution Projects

Rules for execution project settings
The following table describes the rules and precautions regarding the configuration of execution project settings using the
PLC On-board.
Projects that are not usable will not execute even if set to ON.
You cannot turn off all projects.
Entering the execution projects
(1) Press the [LIST] menu to select the list.
(2) Use the up and down arrow keys to move to the position of the line for the project in the list for which the execution is to
be set.
(3) Refer to "Setting selection items in lists" in "Operation Key List :Screen Items (Control)". Pressing the [INPUT] key while
the cursor is in the execution project display field changes the display between [ON] and [OFF].
(4) In accordance with the previously described rules and precautions, select [ON] to execute the project at the set position
or select [OFF] to not execute the project.
Setting Rules and Precautions
569
ON
OFF
ON
IB-1501614-B