M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.13 Corrective Actions to Resolve Errors

5.13.2.4 Displaying of the Ladder in which an Error Occurred

The ladder in which an error has occurred is displayed on the "PLC Diagnostics" screen. By following the operations below,
the ladder in which an error occurred which exists in the project currently opened with the GX Works2 can be displayed in the
edit mode.
Click [Error Jump] (c) on the "PLC Diagnostics" screen
The ladder of the file in which an error has occurred is displayed on another window. Then the cursor moves to the step where
the error has occurred.
The following conditions are required to accurately display the ladder in which an error occurred section.
 The file name and sequence program No. must be displayed in the "Error details" screen.
(In this case, no response or error dialog display will be given even if the button is clicked.)
 A project including the sequence program currently in operation in the CNC controller side must be opened.
(Even when a project not in operation is opened, if the same program name already exists, a ladder different from the
actual one in which an error occurred is displayed. So, be careful.)
 Depending on the type of error, sequence step No. does not show the ladder in which an error occurred accurately.
233