Precautions For Language Setting For Gx Works2 Project - Mitsubishi Electric M800VW Series Manual

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.5 Language

6.5.3 Precautions for Language Setting for GX Works2 Project

When using a GX Works2 project, set the same language to project language setting on GX Works2 setting screen and
language setting of the project.
Select "Tools" - "Language Selection" from GX Works2 menu to set project language. Select a language from the list box and
press "Yes" in the following screen.
For the project language setting on GX Works2 setting screen, refer to "6.16.4 GX Works2 Setting Screen"
PLC data read error
PLC data read error may occur when the project language setting and project language setting on GX Works2 setting screen
do not match. When the following error message is displayed, set the project language setting on GX Works2 setting screen
to the same language as the project language, and read again.
Processing suspended: language settings do not match.
Set project language setting on GX Works2 settings screen to language at creating ladder.
Corruption of Device Comment
Device comments may be corrupted when CNC language parameters do not match project language settings. Set the CNC
language parameter to be the same as that of project language.
External file operation
Corrupted device comments may be stored when external file is operated while CNC language parameters do not match
project language settings. Match the project language setting and project language on GX Works2 setting screen, then
operate an external file again.