6 Explanation of Built-in Editing Function (PLC On-board)
6.17 Device Menus
Screen display items
The following table describes the screen display items on the trace result display screen.
Item name
Connected NC name
Current project No.
Current project label
Alarm message
Left arrow key
Software keyboard
Bit device
Bit device (count)
Bit device (time)
Bit device (display units)
Word device
Word device (count)
Word device (time)
Word device (display units)
Enabled/disabled state of menu keys
The following table describes the conditions upon which menu keys displayed on the trace result display screen are enabled/
disabled.
The menu keys which are not described in the following table are always enabled.
Menu name
Page left feed
Page right feed
Left scroll
Right scroll
Status during screen displays
The following table describes the status when the trace result display screen is displayed.
Item name
Bit device
Bit device (count)
Bit device (time)
Bit device (display units)
Word device
Word device (count)
Word device (time)
Word device (display units)
IB-1501614-B
This displays the name of the connected NC.
This displays the current project number.
This displays the project label.
Alarm messages are displayed when alarms occur.
This is displayed when enabled.
This is displayed only when parameters are enabled.
This displays 7 points of the trace result of bit devices (connect/coil).
(with software keyboard: 4 points display)
The changes of the devices are displayed in chronological order based on the trigger point as
a base point "0".
This displays the number of traces at the cursor position in the displayed bit device field.
The number of traces is indicated as the trigger position is "0", before trigger is negative, and
after trigger is positive.
This displays the trace time (h:m:s) at the cursor position in the bit device display field.
This displays the display scale (number of traces to be displayed) in the bit device display field.
This displays 3 points of the trace result of word devices.
The changes of the values are displayed in chronological order based on the trigger point as a
base point "0".
This displays the number of traces at the cursor position in the displayed word device field.
The number of traces is indicated as the trigger position is "0", before trigger is negative, and
after trigger is positive.
This displays the trace time (h:m:s) at the cursor position in the word device display field.
This displays the display scale in the word device display field.
Condition upon which it is enabled/disabled
Disabled when there is no page to feed.
Disabled when there is no page to feed.
Disabled when there is no object to scroll.
Disabled when there is no object to scroll.
This displays the trace data of the bit device.
This displays the number of traces in the top of trace data.
This displays the trace time in the top of trace data.
This displays "10".
This displays the trace data of the word device.
This displays the number of traces in the top of trace data.
This displays the trace time in the top of trace data.
This displays "16BIT DEC".
Display state
Operation