M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.11 Basic Operation
To use multiple projects
Procedure
Start
Main
Select the current project.
Main
Add the sequence
program to the current
project.
Main/File operation
Add new data
Main/File operation
Return to the main screen.
Main
Write the added sequence
program to ROM.
Main/NC file operation
ROM write
Complete
IB-1501614-B
Operation
Screen position
Menu button
SELECT PROJECT
FILE OPERATION
DATA NEW
DATA NAME
TITLE
ADDITION
NC FILE
ROM WRITE
EXECUTE
316
Select the current operation project.
Transition to the file operation screen.
The add new data popup screen
displays.
Enter the [Data Name] and [Title] for
the sequence program to be added.
Enter the information for the added
data and execute the [ADD] operation.
Return to the main screen.
Repeat this procedure until the
sequence program has been added to
all projects.
Transition to the NC file operation
screen.
The ROM write popup screen displays.
Execute the ROM write operation.