3.2 I/O Device Parameters

Parameters for up to five types of input/output devices can be set in DEV <0> to <4>.
(Note) The parameters are set for each device.
9101 ~
9201 ~
9301 ~
9401 ~
9501 ~
#
Item
9101
DEVICE NAME 0
9201
DEVICE NAME 1
9301
DEVICE NAME 2
9401
DEVICE NAME 3
9501
DEVICE NAME 4
9102
BAUD RATE
9202
9302
9402
9502
9103
STOP BIT
9203
9303
9403
9503
9104
PARITY CHECK
9204
9304
9404
9504
9105
EVEN PARITY
9205
9305
9405
9505
9106
CHR. LENGTH
9206
9306
9406
9506
3. I/O Parameters
3.2 I/O Device Parameters
Set the same settings for device 0.
Set the same settings for device 1.
Set the same settings for device 2.
Set the same settings for device 3.
Set the same settings for device 4.
Contents
Set the device name corresponding to the device
No.
Set a simple name for quick identification.
Set the serial communication speed.
Set the stop bit length used in the start-stop system. 1: 1 (bit)
Specify whether to add the parity check bit to the
data during communication.
Specify the odd or even parity when it is added to
the data.
Set the length of the data bit.
10
Get other manuals https://www.bkmanuals.com
Setting range (unit)
Use alphabet
characters‚ numerals
and symbols to set a
name within 3
characters.
1: 9600 (bps)
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 150
2: 1.5
3: 2
0: Parity bit not added
1: Parity bit added
0: Odd parity
1: Even parity
0: 5 (bit)
1: 6
2: 7
3: 8