M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.18 Parameter Menus
6.18.3 Common Pointer Settings Screen
6.18.3.1 Outline
The initial P number can be checked for common pointers (pointers used to call subroutines from all programs) in the current
project.
Note
(1) Configure common pointers using GX Developer/GX Works2 in range between P0 to P4095.
(2) The initial P number in common pointers is enabled when executing multiple programs.
(3) When executing single programs, leave this blank (press the [SET] button without configuring any settings).
(4) If the common pointer setting is left blank (not configuring any settings) when using multiple programs, this is set to the
default of P1800 or higher.
6.18.3.2 Screen Display Items
The following table describes the screen display items for the common pointer settings screen.
Item name
Connected NC name
Current project No.
Current project label
Alarm message
Left arrow key
Software keyboard
Common pointer No.
Display state
This displays the name of the connected NC.
This displays the current project number.
This displays the project label.
This is displayed when alarms occur.
This is displayed when enabled.
This is displayed only when parameters are enabled.
This displays the initial P number for common pointers.