M800V/M80V Series PLC Development Manual
2 System Configuration of H/W
2.2 Relation of RIO Unit and Devices
(2) Output (DO) signal
Connector for contact output (DO)
B20 pin
A20 pin
(2)
(4)
B01 pin
A01 pin
Note
 The No. of points (devices) will differ according to the RIO unit type.
 The devices shown here show an example for when the station No. of RIO unit is set to "1" and set to "2".
 The A04 and B04 pin analog output (AO, AO*) in the output connector (4) is found only on the RIO unit DX231.
Refer to the section "2.7 Outline of Analog Signal Input Circuit" for details on DX220/DX230 connector.
Set station No. to 1
(2)
(4)
B
A
20
Y00
Y10
19
Y01
Y11
18
Y02
Y12
17
Y03
Y13
16
Y04
Y14
15
Y05
Y15
14
Y06
Y16
13
Y07
Y17
12
Y08
Y18
11
Y09
Y19
10
Y0A
Y1A
09
Y0B
Y1B
08
Y0C
Y1C
07
Y0D
Y1D
06
Y0E
Y1E
05
Y0F
Y1F
04
03
02
+24V
0V
01
+24V
0V
(10)
1
1
2
2
3
3
15
Set station No. to 2
B
A
20
Y20
19
Y21
18
Y22
17
Y23
16
Y24
15
Y25
14
Y26
13
Y27
12
Y28
11
Y29
10
Y2A
09
Y2B
08
Y2C
07
Y2D
06
Y2E
05
Y2F
04
AO
AO*
03
02
+24V
0V
01
+24V
0V
Analog output
(For DX231 only)
Signal
DC+24V IN
0V
FG
Y00
L
Y2F
L
Stabilized
power supply
+24V
0V
FG