M800V/M80V Series PLC Development Manual
2 System Configuration of H/W

2.7 Outline of Analog Signal Input Circuit

2.7 Outline of Analog Signal Input Circuit
 Input circuit
AIO
AI
0V
 Input conditions
Analog input voltage
Max. input rating (*1)
Resolution
Repeatability
Tolerance
(*1) This indicates the input voltage which must not exceed even in an instant.
(*2) Except when the accuracy is affected by the noise.
ADC
-10 V to 10 V
±15 V
|-10 V to +10 V| /4095 = 4.88 mV
Within ±25 mV (*2)
±0.35 V
25