M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)

5.18 Troubleshooting and FAQ

5.18 Troubleshooting and FAQ
#
Item
When sequence programs in the GX Developer format are read to GX Works2, symbolic information, PLC
Problem
message, and device comment cannot be written to the CNC controller.
When the setting for writing symbolic information in the [Symbolic Information] option under [Tool] -> [Options]
on GX Works2 is [High Speed Mode], symbolic information is written to CNC as two files.
1
Scenario
Note the symbolic information was written as one file if it is from GX Developer.
If the number of files to be written to the data area is the maximum in GX Developer, when read to GX Works2,
the number of files exceeds the maximum.
Select [Compatible mode] in the setting for writing symbolic information in the [Symbolic Information] option
Remedies
under [Tool] -> [Options] on GX Works2, and write to the NC.