M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.14 Backing Up Sequence Programs and Other Data

5.14.2.2 Backup Procedure

Backup is executed on the input/output screen of the CNC controller.
Select the transfer symbolic information (CNC controller side) and the transfer target information (personal computer side), to
be transferred on the input/output screen. When transmission is started, the data such as sequence programs of the specified
project stored in the CNC ROM will be backed up in the personal computer.
An example of the input/output screen and the operating procedure are described below.
For details on the input/output screen, refer to the instruction manual of your model.
Setting for the CNC controller
Set the device name, directory, and file name for [A:Dev].
(1) Set [A:Dev]
Select "Memory" with menu keys.
(2) Set [Dir:]
Input the character string "/LAD".
(3) Set [File]
Select [From list] with menu keys and select "PROJECTxx.LAD" (xx: project number to be output) from the file list, and
press [INPUT].
Setting for the personal computer (device name, directory, and file name)
Set the device name, directory, and file name for [B:Dev].
(4) Set [B:Dev]
Select "HD" with menu keys.
(5) Set [Dir:]
Input the character string "/".
(6) Set [File]
Set the file name to be stored. When omitted, "PROJECTxx.LAD" (xx: project number to be output) is assigned.
Transmission
The backup process starts when the menu key [Trnsfr A->B] is pressed.