M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.6 Developing Simple Project
 Restriction on MPS instruction use
Condition: Only up to seven MPS instructions can be used consecutively. When MPP instruction is used, one more MPS
instruction becomes available.
Workaround: When using a ladder containing the number of MPS instructions that exceeds the upper limit, use a substitute
ladder as follows.
Ladder screen on GX Works2
Ladder screen on GX Works2
Ladder block is divided by
M10 device.
Set the NC parameter "#6456/bit0" to "1" to display an error dialog on GX Works2 when sequence programs, which do not
conform to restrictions described in "Restriction on use of ANB instruction and ORB instruction" and "Restriction on MPS
instruction use", are written. This prevents PLC from becoming RUN status. When an error dialog is displayed, use the above
substitute ladder.
Ten MPS instructions are
used consecutively.
Consecutiveness of MPS
instructions is reset by 7 MPP
instructions following 7 MPS
instructions, which enables
additional 3 MPS instructions to
be used.