M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.10 Creating Label

5.10.4 Reading Label Setting on GX Works2

Label setting (CSV format) created using tools such as spreadsheet is read to GX Works2 as follows.

5.10.4.1 Reading to GX Works2

Open the read screen by the following operation in the navigation window on GX Works2.
 Global label
[Project] -> Right-click [Global Label] -> [Read from CSV File]
 Local label for program
[Project] -> [POU] -> [Program] -> [Program Name] -> Right-click [Local Label] -> [Read from CSV File]
 Local labels for function blocks
[Project] -> [POU] -> [FB_Pool] -> [FB name] -> Right-click [Local Label] -> [Read from CSV File]
Select a label setting file on the following screen, and click [Open].

5.10.4.2 Precautions

If the language the label setting file is written in is different from the region setting on Windows, the characters will corrupt
when written to the CNC, and cannot be read properly by built-in edit functions. To avoid this issue, change the Windows
region setting to the appropriate one for the language of the label setting file, before reading the label setting file in the CSV
format to GX Works2.
Refer to "5.17.3 Multi-language Data" for details.