M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.15 Ladder Menus
RUN write execution
When you execute a conversion during PLC RUN, the following message will appear to confirm whether to continue the RUN
write execution.
The following information describes the resulting operation by pressing each menu key.
[When [WRITING DURING RUN] key is pressed]
RUN write is executed. Processing time of RUN write depends on the total number of steps used in the ladder programs and
the points where the steps are written in (from one second or less to several seconds).
The following message will appear when RUN write is completed.
[When [WRITING AFTER STOP] key is pressed]
The PLC stops and the conversion process executes. Once the conversion is complete, the background color of the edited
portion of the ladder screen (gray) changes to white.
After the conversion has been completed, a message confirming whether to have PLC returned to the RUN state is displayed.
If the [YES] menu key is pressed, the PLC continues running. If the [NO] menu key is pressed, the PLC state is not changed.
[When [CANCEL] key is pressed]
PLC will be back to the state before conversion.