M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.6 Developing Simple Project
Operating procedure for simple projects (with labels)
The operating procedure when "use label" is set is described below.
(1) Start the operation screen by the following operation on GX Works2.
[Online] -> [Read from PLC]
(2) Select [Program Memory/Device Memory] in [Target Memory Setting] for [Symbolic Information] on the following screen.
Select "GX Works2 (Simple project)", and click [Execute].
Note
[Program Memory/Device Memory] is the only valid option for [Target Memory Setting].
Click [Refresh] before reading symbolic information.
For details on read parameters before reading symbolic information, refer to "5.5.8.6 Writing and Reading Parameters
to CNC Controller".
When symbolic information is read, labels and FB are also read as well as sequence programs.
When a simple project with labels is selected, a sequence program only by itself cannot be read.