M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.5 Common Items
Saving trace result
(1) Click [Debug] - [Sampling Trace] - [Export CSV Data] to open the "Export CSV Data" window.
(2) Select the location for storage, input a file name, and click [Save].
Note
(1) Trace result data are overwritten every time trace is executed. Save data as a CSV file as necessary.
Retaining trace execution status
The trace execution status is retained after the CNC is turned OFF.
This allows trace to be executed from power ON as follows.
(1) Turn OFF the CNC while trace is being executed.
To check the progress of trace, click [Debug] - [Sampling Trace] - [Display Trace Buffer Condition] to display the "Trace
Data Storage Status" screen.
(2) Turn the CNC power ON again.
(3) Trace is executed at the power ON.
Note
(1) Trace result is erased when the CNC power is turned OFF.
(2) Even when the post-trigger status is active at the CNC power OFF, the tracing at the power ON is always started from the
pre-trigger status.
113
IB-1501614-B