M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.5 Common Items
Example 2: Trace judgment and trace result with device setting
[Setting details]
Trace setting details for example 2
Setting item
Target Memory
File Name
Total Count
Count After Trigger
Additional Information
Data Acquisition Timing Setting  Device
Medium speed ladder scan cycle
Device No.1
Device No.2
Word device 1
1
Trigger
Trigger execution from
GX Works2
Device status when sampling trace is executed at example 2
[Trace result]
Trace result display for example 2
Count
1
Device No.1
Device No.2
Word device 1
2
IB-1501614-B
Setting value
Standard RAM
MAIN
6
4
None
Bit device
Device No.1 ↑
 4
2
3
5
6
7
Trigger input from GX Works2
If the setting for trigger point is "At the time of TRACE
instruction execution", it is ignored and changed to "At
the time of manual execution".
2
3
4
5
4
7
8
10
Setting item
Trigger Condition Setting
Device setting
8
9
10
11
12
13
<- Trace scan at trace start is count 1.
6
<- Trace is executed only for the scan where
device No.1 turns ON from OFF.
12
Device data for the scan when trigger is executed
is saved
116
Setting value
 At the time of TRACE instruc-
tion execution
 Bit device
Device No.1
Device No.2
 Word device
Word device 1
14
15