ST STM32F405 Reference Manual page 544

Hide thumbs Also See for STM32F405:
Table of Contents

Advertisement

Advanced-control timers (TIM1 and TIM8)
in the TIMx_CR1 register. Moreover, the DIR and CMS bits must not be changed at the
same time by the software.
Writing to the counter while running in center-aligned mode is not recommended as it
can lead to unexpected results. In particular:
The safest way to use center-aligned mode is to generate an update by software
(setting the UG bit in the TIMx_EGR register) just before starting the counter and not to
write the counter while it is running.
17.3.11
Complementary outputs and dead-time insertion
The advanced-control timers (TIM1 and TIM8) can output two complementary signals and
manage the switching-off and the switching-on instants of the outputs.
This time is generally known as dead-time and it has to be adjust it depending on the
devices connected to the outputs and their characteristics (intrinsic delays of level-shifters,
delays due to power switches...)
User can select the polarity of the outputs (main output OCx or complementary OCxN)
independently for each output. This is done by writing to the CCxP and CCxNP bits in the
TIMx_CCER register.
The complementary signals OCx and OCxN are activated by a combination of several
control bits: the CCxE and CCxNE bits in the TIMx_CCER register and the MOE, OISx,
OISxN, OSSI and OSSR bits in the TIMx_BDTR and TIMx_CR2 registers. Refer to
for more details. In particular, the dead-time is activated when switching to the IDLE state
(MOE falling down to 0).
Dead-time insertion is enabled by setting both CCxE and CCxNE bits, and the MOE bit if the
break circuit is present. DTG[7:0] bits of the TIMx_BDTR register are used to control the
dead-time generation for all channels. From a reference waveform OCxREF, it generates 2
outputs OCx and OCxN. If OCx and OCxN are active high:
The OCx output signal is the same as the reference signal except for the rising edge,
which is delayed relative to the reference rising edge.
The OCxN output signal is the opposite of the reference signal except for the rising
edge, which is delayed relative to the reference falling edge.
If the delay is greater than the width of the active output (OCx or OCxN) then the
corresponding pulse is not generated.
The following figures show the relationships between the output signals of the dead-time
generator and the reference signal OCxREF. (we suppose CCxP=0, CCxNP=0, MOE=1,
CCxE=1 and CCxNE=1 in these examples)
544/1749
The direction is not updated if the user writes a value in the counter greater than
the auto-reload value (TIMx_CNT>TIMx_ARR). For example, if the counter was
counting up, it will continue to count up.
The direction is updated if the user writes 0 or write the TIMx_ARR value in the
counter but no Update Event UEV is generated.
RM0090 Rev 18
RM0090
Table 95

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STM32F405 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF