Table 228. I2C-Smbus Specification Clock Timings - STMicroelectronics STM32WL5 Series Reference Manual

Advanced arm-based 32-bit mcus with sub-ghz radio solution
Table of Contents

Advertisement

RM0453
2
Caution:
To be I
C or SMBus compliant, the master clock must respect the timings given in the
following table.
Symbol
f
SCL clock frequency
SCL
t
Hold time (repeated) START condition
HD:STA
Set-up time for a repeated START
t
SU:STA
condition
t
Set-up time for STOP condition
SU:STO
Bus free time between a STOP and
t
BUF
START condition
t
Low period of the SCL clock
LOW
t
Period of the SCL clock
HIGH
t
Rise time of both SDA and SCL signals
r
t
Fall time of both SDA and SCL signals
f
Note:
SCLL is also used to generate the
the
t
HD:STA
Refer to
Master communication initialization (address phase)
In order to initiate the communication, the user must program the following parameters for
the addressed slave in the I2C_CR2 register:
Addressing mode (7-bit or 10-bit): ADD10
Slave address to be sent: SADD[9:0]
Transfer direction: RD_WRN
In case of 10-bit address read: HEAD10R bit. HEAD10R must be configure to indicate
if the complete address sequence must be sent, or only the header in case of a
direction change.
The number of bytes to be transferred: NBYTES[7:0]. If the number of bytes is equal to
or greater than 255 bytes, NBYTES[7:0] must initially be filled with 0xFF.
The user must then set the START bit in I2C_CR2 register. Changing all the above bits is
not allowed when START bit is set.
Then the master automatically sends the START condition followed by the slave address as
soon as it detects that the bus is free (BUSY = 0) and after a delay of t
In case of an arbitration loss, the master automatically switches back to slave mode and can
acknowledge its own address if it is addressed as a slave.
2
Table 228. I
C-SMBus specification clock timings
Parameter
and t
timings.
SU:STO
Section 34.4.10
for examples of I2C_TIMINGR settings vs. I2CCLK frequency.
Inter-integrated circuit (I2C) interface
Standard-
Fast-mode
mode (Sm)
(Fm)
Min
Max
Min
Max
-
100
-
4.0
-
0.6
4.7
-
0.6
4.0
-
0.6
4.7
-
1.3
4.7
-
1.3
4.0
-
0.6
-
1000
-
-
300
-
t
and t
timings, and
BUF
SU:STA
RM0453 Rev 5
Fast-mode
SMBus
Plus (Fm+)
Min
Max
Min
400
-
1000
-
-
0.26
-
4.0
-
0.26
-
4.7
-
0.26
-
4.0
-
0.5
-
4.7
-
0.5
-
4.7
-
0.26
-
4.0
300
-
120
-
300
-
120
-
SCLH is also used to generate
.
BUF
Unit
Max
100
kHz
-
-
-
µs
-
-
50
1000
ns
300
1071/1450
1113