CHAPTER 9
ENCODER PARAMETERS

USER PARAMETER DATA

User parameter data listed in the table below is sent to the encoder in the start-up
phase.
PARAMETER
Type of encoder
Code sequence
Class 4 functionality
G1_XIST1 Preset control
Scaling function control
Alarm channel control
Compatibility mode
Measuring unis /
Revolution
Total measuring range
Maximum tolerated fail-
ures of Master Sign-Of-
Life
Velocity measuring unit
62
AMT58...PN
DATA
INDEX
TYPE
516
BitArea
517
Bit
518
Bit
519
Bit
520
Bit
521
Bit
522
Bit
523
UnSigned32
524
UnSigned32
525
UnSigned8
526
BitArea
DEFAULT
0: AMT58 multiturn 13/14
0 (CW)
1 (enabled)
0 (enabled)
0 (disabled)
0 (disabled)
1 (disabled = profile version
V4.1)
8.192
134.217.728
1
0 (Steps/s)
COMMENT
Only supported in
Compatibility Mode
Only supported in
Compatibility Mode