ENCODER PARAMETERS

Class 4 functionality

[Index 518]
For any information on the implemented Application Classes refer to "
definition" on page 45
If it is enabled, Code sequence, G1_XIST1 Preset control and Scaling function control
affect the position value in G1_XIST1 and G1_XIST2. However the preset will not affect
the position value in G1_XIST1 if the parameter G1_XIST1 Preset control is disabled; it
will always affect G1_XIST2 instead.
Default = 1 = enable (min. = 0, max. = 1)

G1_XIST1 Preset control

[Index 519]
This parameter is available only if Class 4 functionality is enabled.
This parameter controls the effect of a preset on the G1_XIST1 current value. When it is
enabled, Preset will affect the position value in G1_XIST1.
Default = 0 = enable (min. = 0, max. = 1)
CAUTION
NOTE
64
AMT58...PN
.
ATTRIBUTE
Code sequence, G1_XIST1 Preset control
Disable
and Scaling function control disabled
Code sequence, G1_XIST1 Preset control
Enable
and Scaling function control enabled
ATTRIBUTE
G1_XIST1 is affected by a Preset com-
Enable
mand
Disable
Preset does not affect G1_XIST1
G1_XIST1 Preset control is disabled by setting the value 1.
There is no functionality of this parameter if the Class 4 functionality
parameter is disabled.
MEANING