Datalogic AMT58 Series Manual page 319

Absolute encoders
Hide thumbs Also See for AMT58 Series:
Table of Contents

Advertisement

default value. Otherwise, if the node address is set via software
(i.e. all dip-switches for setting the node have LOW logic level = 0)
it retains the set value, unless a software procedure for setting a
new address is forced at power on.
Default = C000 0480h+NodeID (no RTR, COB-ID)
 02 Transmission type [Unsigned8, rw]
Default = FEh (cyclic transmission)
NOTE
- Transmission of PDO1, PDO2, PDO3 and PDO4 messages can be
enabled (or disabled) setting to "0" (or "1") the most significant bit
(MSB) used by PDO (object 180xh, sub1).
- Cyclic transmission or synchronous transmission can be modified
setting the object
180xh
01h: synchronous transmission at each SYNC command;
02h: synchronous transmission after two SYNC commands;
...
FEh: cyclic transmission.
1A00-01 PDO1 mapping parameter
[Unsig32, rw]
This object contains the mapped position value of the encoder
according to DS406 device profile.
Default = 6004 0020h
1A01-01 PDO2 mapping parameter
[Unsig32, rw]
See object
1A00-01 PDO1 mapping
1A02-01 PDO3 mapping parameter
[Unsig32, rw]
See object
1A00-01 PDO1 mapping
1A03-01 PDO4 mapping parameter
[Unsig32, rw]
This object contains the mapped velocity value of the encoder
according to the manufacturer profile.
Default = 3006 0020h
sub 2:
parameter.
parameter.
AMT58x-CB CANopen®