AMT58x-EC EtherCAT®
4.2 Ground connection
Minimize noise by connecting the shield and/or the connector
housing and/or the frame to ground. Make sure that ground is not
affected by noise. The connection point to ground can be situated
both on the device side and on user's side. The best solution to
minimize the interference must be carried out by the user. You are
advised to provide the ground connection as close as possible to the
encoder. We suggest using the ground point provided in the cap (see
Figure, use 1 TCEI M3 x 6 cylindrical head screw with 2 tooth lock
washers).
4.3 Diagnostic LEDs
Five LEDs located in the rear side of the connection cap are
designed to show the operating or fault status of the EtherCAT®
interface.
Link/ Activity
(yellow)
OFF
FLICKERING
ON
RUN (green)
OFF
BLINKING
SINGLE FLASH
ON
PWR (green)
OFF
ON
ERR (red)
OFF
FLICKERING
FLICKERING
BLINKING
SINGLE FLASH
DOUBLE FLASH
ON
8
it shows the status of the physical link and the
activity in this link
condition: port closed, link: YES, activity: N.A.
condition: port open, link: YES, activity: YES
condition: port open, link: YES, activity: NO
it shows the status of the EtherCAT State
Machine (ESM)
encoder is in
INIT
encoder is in
PRE-OPERATIONAL
encoder is in
SAFE-OPERATIONAL
encoder is in
OPERATIONAL
it shows the power supply status
encoder is switched OFF
encoder is switched ON
it shows the error status
no error
error on loading parameters from flash
memory at start-up
encoder parameters have not been saved
correctly on flash memory
invalid configuration
local error (see ETG1000.6)
watchdog timeout
memory error and ESC controller not active
status
status
status
status