Scaling function control

[Index 520]
This parameter enables / disables the Scaling function. When this parameter is disabled,
the device uses the hardware singleturn and multiturn resolutions; when it is enabled,
the device uses the resolutions set next to the parameters Measuring units / Revolution
and Total measuring range. Refer also to "
Default = 0 = disable (min. = 0, max. = 1)
NOTE

Alarm channel control

[Index 521]
This parameter enables / disables the encoder specific Alarm channel transferred as
Channel Related Diagnosis. This functionality is used to limit the amount of data sent in
isochronous mode.
If the value is zero (0 = default value), only the communication related alarms are sent
via the alarm channel. If the value is one (1), also the encoder specific faults and warn-
ings are sent via the alarm channel.
Default = 0 = disable (min. = 0, max. = 1)
NOTE
ATTRIBUTE
Disable
Scaling function disabled
Enable
Scaling function enabled
There is no functionality of this parameter if the Class 4 functionality
parameter is disabled.
ATTRIBUTE
Disable
No profile specific diagnosis
Enable
Profile specific diagnosis
This parameter is only supported in compatibility mode (see " Compatibility
Mode" on page 66 ).
Scaling function parameters" on page 67
MEANING
MEANING
USER PARAMETER DATA
.
VALUE
0
1
VALUE
0
1
65
INSTRUCTION MANUAL