Datalogic AMT58 Series Manual page 88

Absolute encoders
Hide thumbs Also See for AMT58 Series:
Table of Contents

Advertisement

6.4 DDLM_Set_Prm
When the system is turned on, configuration data set by the operator
is sent to the absolute encoder by the controller (DDLM_Set_Prm
mode). Parameters transmission depends on the configuration
chosen by the operator. Customarily data is sent automatically while
data setting is carried out through a user's interface available in the
controller's software (for instance, STEP7, see section "5.1
Configuring the encoder via Siemens STEP7" on page 14).
However sometimes it is necessary to set some bits and bytes
according to the working specifications you want to set.
Data transmission is carried out according to the specifications of the
encoder profile, as shown in the following tables.
DDLM_Set_Prm:
Byte
0 ... 9
10
11 ... 12
13 ... 16
17 ... 20
6.4.1 Byte 10 - Operating parameters
Bit
0
1
Class 2 functionality
2
3
4, 5, 6, 7
Default values are highlighted in bold.
Reserved for PROFIBUS
Operating parameters
bit 0
Code sequence
bit 1
Class 2 functionality
bit 2
bit 3
Scaling function
Bits 4 ... 7
Counts per revolution
Function
Code sequence
Reserved
Scaling function
Reserved
AMT58x-PB Profibus®
Parameter
network
Reserved
Reserved
Total resolution
Reserved
bit = 0
bit = 1
CW
CCW
disabled
enabled
disabled
enabled
31