Absolute encoders
Hide thumbs Also See for AMT58 Series:
Table of Contents

Advertisement

4-7
Extended
Device
status
8
Minor
Recoverable
fault
9
Minor
Unrecoverable
fault
10
Major
Recoverable
fault
11
Major
Unrecoverable
fault
12-15
Reserved
For any further information on status instance attribute refer to the
publication "The CIP Networks Library. Volume I. Common Industrial
Protocol (CIP™)".
01-01-06 Serial number
[UDINT, ro]
This attribute is a number used in conjunction with the Vendor ID to
form a unique identifier for each device on any CIP network.
01-01-07 Product name
[SHORT_STRING, ro]
Default = 05 4C 49 4B 41 20h = "AMT58"
AMT58x-DN DeviceNET®
Bits are defined as follows:
0000
Self-Testing or Unknown
0
Firmware Update in Progress
0
At least one faulted I/O connection
0
No I/O connections established
0
Non-Volatile Configuration bad
0
Major Fault – either bit 10 or bit 11 is
true (1)
0
At least one I/O connection in run
mode
0
At
least
one
established, all in idle mode
1 0 0 0
Reserved, shall be 0
1 0 0 1
1 0 1 0
Vendor/Product specific
...
1 1 1 1
TRUE indicates the device detected a
problem with itself, which is thought to
be recoverable. The problem does not
cause the device to go into one of the
faulted states.
TRUE indicates the device detected a
problem with itself, which is thought to
be unrecoverable. The problem does
not cause the device to go into one of
the faulted states.
TRUE indicates the device detected a
problem with itself, which caused the
device
to
go
Recoverable Fault" state.
TRUE indicates the device detected a
problem with itself, which caused the
device
to
go
Unrecoverable Fault" state.
Reserved, shall be 0
I/O
connection
into
the
"Major
into
the
"Major
37