Datalogic AMT58 Series Manual page 374

Absolute encoders
Hide thumbs Also See for AMT58 Series:
Table of Contents

Advertisement

AMT58x-DN DeviceNET®
Example
Allocation choice =
01h: used to read and write configuration parameters without "I/O
Messages".
03h: activate Polled communication.
61h: activate Cyclic mode communication without ACK.
6.4.4 Message data transfer
These messages are meant to set, read, save or restore
configuration parameters.
Data transfer request:
Byte
bit7
bit6
0
F=0
0
1
R/R=0
2
3
4
5...7
Data transfer response:
Byte
bit7
bit6
0
F=0
0
1
R/R=1
2...7
Service code, Class ID, Instance ID and Attribute ID are meant to set
the type and content of data bytes. They must be specified according
to the "Object dictionary" (see section "6.5 Object dictionary").
34
bit5
bit4
bit3
Master MAC-ID
Service Code
Class ID
Instance ID
Attribute ID
Data byte
bit5
bit4
bit3
Master MAC-ID
Service Code
Data byte
bit2
bit1
bit0
bit2
bit1
bit0

Advertisement