Datalogic AMT58 Series Manual page 381

Absolute encoders
Hide thumbs Also See for AMT58 Series:
Table of Contents

Advertisement

05-Inst-07 Produced connection size
[UINT, ro]
Maximum number of bytes transmitted in this connection.
05-Inst-08 Consumed connection size
[UINT, ro]
Maximum number of bytes received in this connection.
05-Inst-09 Expected packet rate
[UINT, rw]
This attribute is meant to set the time between two subsequent "I/O
message" transmissions (Transmission Trigger Timer) and the
Inactivity/Watchdog Timer.
05-Inst-0C Watchdog time-out action
[USINT, ro]
This attribute defines the action the Connection Object should
perform when the Inactivity/Watchdog Timer gap has expired.
Default = 01h: the Connection Class automatically closes the
connection after the Inactivity/Watchdog Timer gap has expired.
05-Inst-0D Produced connection path length
[UINT, ro]
This attribute specifies the number of bytes the
connection path
attribute is fitted with.
05-Inst-0E Produced connection path
[EPATH, ro]
This attribute is fitted with a byte stream which defines the
Application Object(s) whose data is to be produced by this
Connection Object.
05-Inst-0F Consumed connection path length
[UINT, ro]
This attribute specifies the number of bytes the
connection path
attribute is fitted with.
AMT58x-DN DeviceNET®
05-Inst-0E Produced
05-Inst-10 Consumed
41

Advertisement

Chapters

Table of Contents
loading

Table of Contents