To change any value enter a suitable value in the WRITE column next to the desired
parameter and then press the button between the boxes to confirm. The values have to
be set either in decimal notation or by using the drop-down menu (when available).
For complete information on the available parameters please refer to
Parameters, starting on page 62
Example
The Code sequence parameter is currently set to "CW" (see the READ box in the first
line of the Figure 52 above). To change the set value enter a suitable value in the corre-
sponding WRITE box of the same line through the drop-down menu and then press the
CODE SEQUENCE button to confirm.
Example
The Measuring units / Revolution parameter is currently set to "8192" (see the READ
box in the third last line of the Figure 52 above). To change the set value enter a suitable
value in the corresponding WRITE box of the same line and then press the MEASUR.
UNITS/REV. button to confirm.
Please note that, after pressing the button between the boxes, the set
value is instantly saved in a permanent way in the parameter.
NOTE
At each confirmation of the set parameters, a message will appear under
the buttons (see the
operation has been accomplished properly or an error occurred (for exam-
NOTE
ple
Command was set correctly
if something went wrong).
Press the Homepage command to move back to the Web server Home page.
.
No Command sent
message). It informs whether the
if everything went well; or
SETTING THE PARAMETERS
Encoder
Command Error!