Datalogic AMT58 Series Manual page 303

Absolute encoders
Hide thumbs Also See for AMT58 Series:
Table of Contents

Advertisement

4.4 Connection cap with M12 connectors
Connection cap is fitted with two M12 connectors with pin-out in
compliance with CANopen® standard. Therefore you can use
standard CAN cables commercially available.
M12 connector
A coding
(frontal side)
M12
Case
1
1
2
3
4
5
1
CAN Shield is also connected to pin 1 to allow the connection of
the shield even if the plug connector has a plastic case.
4.5 Connection of the shield
Disentangle and shorten the shielding 1 and then bend it over the
part 2; finally place the ring nut 3 of the connector. Be sure that the
shielding 1 is in tight contact with the ring nut 3.
AMT58x-CB CANopen®
male
female
(BUS IN)
(BUS OUT)
Description
CAN Shield
+10VDC +30VDC
Supply voltage
0 VDC Supply voltage
CAN High
CAN Low
9

Advertisement

Chapters

Table of Contents
loading

Table of Contents