AMT58x-DN DeviceNET®
23-01-67 Data Tx in COS/Cyclic mode
[USINT, rw]
This parameter is meant to set which input data is sent when Change
Of State
(COS) / Cyclic mode connection is enabled.
00: Position value
01: Position value + velocity
23-01-68 Auto-save parameters
[BOOL, rw]
Yes: when new parameters are set, the encoder waits 5 seconds
and then saves automatically all new values on EPROM.
No: new parameters are not saved on EPROM automatically.
To save new values, Class Instance Editor must be used
(default value; see section "5.4 Save parameter with
RSNetWorx").
NOTE
To save new parameters execute the "Save parameters" function
(see Errore. L'origine riferimento non è stata trovata.section "7.1
Read and set parameters").
When the power is turned off or in case of "Reset node" and "Restore
node" commands, parameters not saved are lost.