Datalogic AMT58 Series Manual page 307

Absolute encoders
Hide thumbs Also See for AMT58 Series:
Table of Contents

Advertisement

5. Quick reference
Using the default settings provided by the manufacturer, you can
switch on the device and read immediately its position.
Follow the instructions below to:
read the device resolution;
set the
Operational
read the current position (cyclic mode and/or sync mode).
Default Baud rate and Node-ID are:
Baud rate = 500 Kbit/s
Node-ID = 1
Read resolution per revolution
revolution
Master  Encoder
COB-ID
Cmd
601
40
Encoder  Master
COB-ID
Cmd
581
43
steps/rev. = ( (A3<<24) | (A2<<16) | (A1<<8) | A0 )
Read number of revolutions
Master  Encoder
COB-ID
Cmd
601
40
Encoder  Master
COB-ID
Cmd
581
43
N. rev. =( (B3<<24) | (B2<<16) | (B1<<8) | B0 )
Set cyclic time
6200-00 Cyclic time
Master  Encoder
COB-ID
Cmd
600+ID
2B
Encoder  Master
COB-ID
Cmd
580+ID
60
Set
Operational
mode
Master  Encoder
COB-ID
Cmd
000
01
Read the position every 100 ms
Encoder  Master
COB-ID
Byte 0
181
Low
mode;
6501-00 Hardware counts per
Index
Sub
01
65
00
-
Index
Sub
01
65
01
A0
6502-00 Hardware number of turns
Index
Sub
02
65
00
-
Index
Sub
02
65
01
B0
(100 ms = 64h)
Index
Sub
00
62
00
64
Index
Sub
00
62
00
00
Node
01
Byte 1
Byte 2
...
AMT58x-CB CANopen®
Process data
-
-
-
Process data
A1
A2
A3
Process data
-
-
-
Process data
B1
B2
B3
Process data
00
-
-
Process data
00
-
-
Byte 3
...
High
13

Advertisement

Chapters

Table of Contents
loading

Table of Contents