ELECTRICAL CONNECTIONS

PWR POWER SUPPLY CONNECTOR

M12 4-pin male connector with A coding is used for power supply.

P1 PORT1 AND P2 PORT2 CONNECTORS

Two M12 4-pin female connectors with D coding are used for Ethernet connection
through port 1 and port 2.
The ports are equal and interchangeable - if only one connection is required, either port
can be used. The Ethernet interface supports 100 Mbit/s, full-duplex operation.

NETWORK CONFIGURATION: CABLES, HUBS, SWITCHES

PROFINET is based on a 100 Mbps, full-duplex Ethernet network. Faster communication
is also possible on all transmission sections (e.g., between switches, PC systems, or cam-
era systems).
Using Ethernet several topologies of connection are supported by Profinet networks:
line, tree, daisy-chain, star, etc. Furthermore, Profinet networks can be configured in
almost any topology in the same structure.
The connection of PROFINET IO field devices occurs exclusively with switches as net-
work components. Switches typically integrated in the field device are used for this
(with 2 ports assigned). PROFINET-suitable switches must support "autonegotiation"
(negotiating of transmission parameters) and "autocrossover" (autonomous crossing of
send and receive lines).
Cables and connectors comply with the Profinet specifications. The cabling guide
defines for all Conformance Classes a 2-pair cable according to IEC 61784-5- 3.
Standard Profinet cables commercially available can be used.
8
AMT58...PN
DESCRIPTION
+10Vdc +30Vdc
not connected
0Vdc
not connected
DESCRIPTION
Tx Data +
Rx Data +
Tx Data -
Rx Data -
PIN
1
2
3
4
PIN
1
2
3
4