Datalogic AMT58 Series Manual page 155

Absolute encoders
Hide thumbs Also See for AMT58 Series:
Table of Contents

Advertisement

AMT58x-EC EtherCAT®
100A-00 Software version
[String, ro]
It shows the software version of the device.
1010-01 Store parameters
[Unsigned32, rw]
Use this object to save all parameters on the non-volatile memory.
Write "save" in ASCII code in the data bytes:
Master
Encoder
Cmd
Index
23
10
10
Encoder
Master (confirmation)
Cmd
Index
60
10
10
1011-01 Restore default parameters
[Unsigned32, rw]
This object allows you to restore all parameters to default values.
The default parameters are set at the factory by Datalogic
Automation engineers to allow the operator to run the device for
standard operation in a safe mode. A list of machine data and
relevant default parameters preset by Datalogic Automation s.r.l.
engineers is available on page 56.
Write "load" in ASCII code in the data bytes:
Master
Encoder
Cmd
Index
23
11
10
Encoder
Master (confirmation)
Cmd
Index
60
11
10
NOTE
To save the default values execute the "Store parameters" function
(see object
1010-01 Store
off, parameters not saved are lost.
46
Cmd specific data
Sub
01
73
61
Cmd specific data
Sub
01
00
00
Cmd specific data
Sub
01
6C
6F
Cmd specific data
Sub
01
00
00
parameters). When the power is turned
Data
76
65
Data
00
00
Data
61
64
Data
00
00

Advertisement

Chapters

Table of Contents
loading