AMT58x-CB CANopen®
1010-01 Store parameters
[Unsigned32, rw]
Use this object to save all parameters on non-volatile memory.
Write "save" (ASCII code in hexadecimal form) in the data bytes:
Master  Encoder
Cm
COB-ID
d
600+ID
23
10
Encoder  Master (confirmation)
Cm
COB-ID
d
580+ID
60
10
1011-01 Restore default parameters
[Unsig32, rw]
This object allows the operator to restore all parameters to default
values (default values are set at the factory by Datalogic Automation
engineers to allow the operator to run the device for standard
operation in a safe mode).
Write "load" (ASCII code in hexadecimal form) in the data bytes and
then issue a Reset node command:
Master  Encoder
COB-ID
Cmd
600+ID
23
Encoder  Master (confirmation)
COB-ID
Cmd
580+ID
60
Master  Encoder (Reset node)
COB-ID
Cmd
000
81
Encoder  Master (Boot-up)
COB-ID
Cmd
700+ID
00
NOTE
Save default values using the store parameters function (see object
1010-01 Store
parameters).
22
Index
Sub
10
01
73
Index
Sub
10
01
00
Index
Sub
11
10
01
6C
Index
Sub
11
10
01
00
Slave ID
ID
Data bytes
61
76
65
Data bytes
00
00
00
Data bytes
6F
61
64
Data bytes
00
00
00