AMT58x-PB Profibus®
3 - Mounting instructions
WARNING
Installation has to be carried out by qualified personnel only, with
power supply disconnected and mechanical parts compulsorily in
stop.
Never force the rotation of the shaft manually, it could cause
irreparable damage!
3.1 Solid shaft encoders
• Mount the flexible coupling 1 on the encoder shaft;
• fix the encoder to the flange 2 (or to the mounting bell) by means
of screws 3;
• secure the flange 2 to the support (or the mounting bell to the
motor);
• mount the flexible coupling 1 on the motor shaft;
• make sure the misalignment tolerances of the flexible coupling 1
are respected.
3.1.1 Customary installation
AMT58
3.1.2 Installation using fixing clamps (optional kit code ST-58-KIT)
AMT58
4
a [mm] b [mm] c [mm] d [mm]
36 H7
48
-
a [mm] b [mm] c [mm] d [mm]
36 H7
-
67
-
-