2.5

POWER SUPPLY CONNECTIONS

All versions of DP1100 are powered from the AC mains (see paragraph 1.2).
A connection cable terminated with the 4 pin male connector provided with
the package is used.
Figure 2.9 - Power supply connector - Cable side view
2.6

MAIN SERIAL INTERFACE CONNECTIONS

The signals relative to the following serial interface types are available for the
DP1100 main serial interface:
EIA RS232
EIA RS485 POLLED
EIA RS485 NON POLLED
20mA CURRENT LOOP
DP1100 automatically recognizes the type of interface selected at each
power on of the decoder.
If the recognized interface type is not compatible with the current
communication handshaking, then the system forces the XON/XOFF
protocol.
The parameters relative to the main interface (baud rate, data bits, etc.) can
be defined using the Winhost utility program or Keyboard Mode programming
or Host Mode programming. For more details refer to the section "Main
Interface Menu" in the Help On Line of the Winhost utility program.
A.C. CONNECTION
GND
3
LINE
1
4 PIN MALE
CONNECTOR
NEUTRAL
DP1100