Goodrive350-19 series VFD for crane
Function
code
function selection
P05.45
HDIB lower limit frequency
Corresponding setting of
P05.46
HDIB lower limit frequency
P05.47
HDIB upper limit frequency P05.45–50.000kHz
Corresponding setting of
P05.48
HDIB upper limit frequency
HDIB frequency input filter
P05.49
P05.50
AI1 input signal type
Note: When you set P90.04=1 and use the analog reference frequency, use terminals to give
the forward and reverse running commands.

6.5.10 Analog output

The VFD carries one analog output terminal (0–10V/0–20mA) and one high-speed pulse output
terminal. Analog output signals can be filtered separately, and the proportional relation can be
adjusted by setting the max. value, min. value, and the percentage of their corresponding output.
Analog output signal can output motor speed, output frequency, output current, motor torque and
motor power at a certain proportion.
0
1
2
3
.
.
.
.
P06.00
.
(HDO output type)
.
0
19
1
20
0: Open collector high-speed
P06.00
pulse output
1: Open-collector output
Terminal output is described as follows:
Name
1: Reserved
2: Input set through encoder, used
together with HDIA
0.000 kHz–P05.47
-300.0%–300.0%
-300.0%–300.0%
0.000s–10.000s
time
0–1
0: Voltage
1: Current
Analog output selection
P06.14
(Default value is 0)
P06.16
(Default value is 0)
Description
Analog output curve setting
P06.17
P06.18
P06.19
P06.20
P06.27
P06.28
P06.29
P06.30
-173-
Basic operation guidelines
Default
0.000kHz
0.0%
50.000kHz
100.0%
0.030s
0
Analog output filter
P06.21
P06.31
AO1
HDO