Function
Name
code
P92.38 Enabling overload
Weighing
P92.39
calibration
P92.40
Peeled loading
Non-empty
P92.41
loading
P92.42
Peeled torque
P92.43
Loaded torque
Description
Output frequency
Set frequency
0.5Hz
P92.37
Output current
P92.36
Fault state
0–2
0: Disable
1: Torque overload
Determined by P92.04 and P92.05.
2: Weight overload
Determined by P92.39–P92.46.
Setting range of P92.39: 0–2
0: Normal mode
1: Peeled autotuning
2: Loaded autotuning
This parameter is automatically cleared after
autotuning is completed.
P92.40 setting range: 0.0–20.00t
P92.41 setting range: 0.0–20.00t
P92.42 Setting range: 0–250.0% (of the motor
rated torque)
P92.43 Setting range: 0–250.0% (of the motor
rated torque)
For peeled autotuning, when P92.39=1, the LED
keypad displays "LoAd1". After pressing "Run",
the autotuning starts, and the obtained torque
value is automatically saved to P92.42. In
addition, the VFD decelerates to stop. When the
VFD stops, the LED keypad does not display
"LoAd1".
For loaded autotuning, when you have entered
the weight to P92.41 and set P92.39=2, the LED
keyapd displays "LoAd2". After pressing "Run",
-360-
E-ds
Function parameter list
Default
Modify
○
0
◎
0
○
0.00
○
0.00
○
0.0%
○
0.0%