Goodrive350-19 series VFD for crane
Function
Name
code
FDT1 electrical
P08.32
level detection
value
FDT1 lagging
P08.33
detection value
FDT2 electrical
P08.34
level detection
value
FDT2 lagging
P08.35
detection value
Detection value
P08.36
for frequency
being reached
Description
Tens place: indicates whether to enable
switchover during running
0: Disable
1: Enable
When the output frequency exceeds the
corresponding frequency of FDT electrical level,
the multifunction digital output terminal
continuously outputs the signal of "Frequency
level detection FDT". The signal is invalid only
when the output frequency decreases to a value
lower than the frequency corresponding to (FDT
electrical level—FDT lagging detection value).
Output frequency f
FDT level
Y1,
RO1, RO2
P08.32
setting range:
output frequency)
P08.33
setting range: 0.0–100.0% (FDT1
electrical level)
P08.34
setting range:
output frequency)
P08.35
setting range: 0.0–100.0% (FDT2
electrical level)
When the output frequency is within the
detection range, the multifunction digital output
terminal outputs the signal of "Frequency
reached".
-260-
FDT lag
Time t
Time t
0.00Hz–P00.03
(Max.
0.00Hz–P00.03
(Max.
Function parameter list
Default
Modify
○
50.00Hz
○
5.0%
○
50.00Hz
○
5.0%
○
0.00Hz
Need help?
Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?