Goodrive350-19 series VFD for crane
Function
Name
code
Speed of spindle
P22.01
orientation
DEC time of
P22.02
spindle orientation
Spindle zeroing
P22.03
position 0
Spindle zeroing
P22.04
position 1
Spindle zeroing
P22.05
position 2
Spindle zeroing
P22.06
position 3
Spindle
P22.07
scale-division
angle 1
Spindle
P22.08
scale-division
angle 2
Description
1: Calibration in real time
Bit8: Action selection after zeroing signal
cancellation (electric level type)
0: Switch to speed mode
1: Position lock mode
Bit9: Positioning completion signal selection
0: Electrical level signal
1: Pulse signal
Bit10: Z pulse signal source
0: Motor
1: Spindle
Bit11–15: Reserved
During spindle orientation, the speed of the
position point of orientation will be searched,
and then it will switch over to position control
orientation.
Setting range: 0.00–100.00Hz
DEC time of spindle orientation.
Spindle orientation deceleration time
means the time needed for the VFD to
decelerate from Max. output frequency
(
) to 0Hz.
P00.03
Setting range: 0.0–100.0s
You can select four spindle zeroing positions by
terminals (functions 46 and 47).
Setting range: 0–39999
Setting range: 0–39999
Setting range: 0–39999
Setting range: 0–39999
You can select seven spindle scale-division
angles by terminals (functions 48, 49, and 50).
Setting range: 0.00–359.99
Setting range: 0.00–359.99
-308-
Function parameter list
Default
Modify
10.00Hz
3.0s
0
0
0
0
15.00
30.00